Do the four earlier verdicts survive the refitted energy model?
Yes. All four still pass; the two controls reproduced exactly, and the ordering temperatures moved less than predicted, by −37 to +133 K.
In the log: Re-measuring E74's ladder under the anchored expansion: prediction
mixedDate not stated in the log; it was written between the commit of 2026-09-13 08:16 and the first commit that contains it, 2026-09-16 02:04unclassified0 predictions · 0 result paragraphsEXPERIMENTS.md lines 4500–4529
What E82 did and how it came out, drawn from this record and the files it names (book/assets/diagrams/exp/E82.svg).
Results
No result paragraph for this entry was found in the log.
The full record
EXPERIMENTS.md · lines 4500–4529
E82 — Re-measuring E74's ladder under the anchored expansion: prediction
E80 refitted the expansion with the eight elemental corners and withdrew every ordering
temperature in this file. E74's four verdicts rest on them, so they are re-measured here on
the same four compositions, the same settings and the same seeds - only the expansion has
changed.
The control matters more than the headline. The ladder mixes two models, and only one of
them moved. The driving force comes from a MACE relaxation against a MACE-relaxed hull; the
activation energy comes from MACE vacancy formation and MACE nudged-elastic-band barriers.
Neither touches the expansion. Only T_od is a Monte Carlo over the expansion.
Predicted:
drive_cold reproduces to within 2 meV/atom on all four. No expansion is involved.
Q reproduces to within 0.05 eV on all four. Same reason.
T_od moves by more than its old error bar on at least two of the four. The spot
checks in E80 moved MoNbTaW 501 to 635 K and Mo0.62Ta0.38 1077 to 1342 K.
The scatter on T_od falls on at least three of four. In E80 it roughly halved -
+/-182 to +/-79 and +/-202 to +/-45 - which is the argument that the anchored fit is
better rather than merely different.
The verdicts survive, all four still above P = 0.9, because P is carried by the
kinetic discount, and the kinetics are MACE.
A failure of 1 or 2 is the important one. It would mean something moved that the refit
should not have been able to touch, and that I have the pipeline wrong rather than the
physics. A failure of 5 would be a real change of answer and would need E74 rewritten rather
than re-measured.
The prior-expansion results are kept at runs/odt_map/generated_verified_priorCE.jsonl.
Related entries
E74 — The generator's own candidates up the ladder: better than the reference on the hull,…
E80 — Refitting the expansion with the eight elements: prediction