Could that low reading let a separation just above 90 K pass?
No, not at 150 or 120 K, but only because the broad-feature rule caught it; the reading itself dropped below 90 K. Separation reads at 0.67 of its true temperature.
In the log: does rung 1 falsely pass a separation just above 90 K? (pre-registered 2026-09-27 23:00)
falsifiedDate 2026-09-27 23:00, as written in the logrung 1 · ordering0 predictions · 1 result paragraphEXPERIMENTS.md lines 17431–17439, lines 17441–17454
Pre-registration
The pre-registration, as written
E248b — does rung 1 falsely pass a separation just above 90 K? (pre-registered 2026-09-27 23:00)
The same clustering Ising and protocol as E248, at exact T_c = 150 K and 120 K.
Bar, both: p_rung1 ≤ 0.1. A separating alloy must never pass.
Prediction (from E248's 0.70 read factor): 150 K reads about 105 K and fails; 120 K reads about 84 K
and falsely passes (p > 0.5).
If 120 K passes, rung 1's reading gets a clustering rule, pre-registered before use: when the cold
state clusters (α₁ > 0), the size factor is the one measured here (peak/T_c for separation), not the
ordering one.
Results
EXPERIMENTS.md · line 17441
E248b RESULT (2026-09-27 23:09). Same protocol, runs/e248/:
exact T_c
peak
read T (÷0.95)
peak/T_c
p_rung1
verdict
500 K
332 K
349 K
0.664
0.000
not established: broad (FWHM/T 0.66)
150 K
96 K
101 K
0.640
0.000
not established: broad (0.71)
120 K
84 K
88 K
0.700
0.000
not established: broad (0.62)
The bar holds at both temperatures (p ≤ 0.1): no false pass.
The prediction is falsified. 120 K did not pass, but only because the broad-feature rule caught it:
the peak's upper half-width still reaches 90 K. The reading itself was below 90 K.
The read factor for separation is 0.67 ± 0.03 (three temperatures), not ordering's 0.95 ± 0.03.
The gap is real but narrow. A separation at about 95 K would peak near 64 K, its upper half-width would
end near 88 K, short of the window, and it would pass. That would be a false pass inside the window.
The full record
This entry is written in 2 separate places in the log, shown here in log order.
EXPERIMENTS.md · lines 17431–17439
E248b — does rung 1 falsely pass a separation just above 90 K? (pre-registered 2026-09-27 23:00)
The same clustering Ising and protocol as E248, at exact T_c = 150 K and 120 K.
Bar, both: p_rung1 ≤ 0.1. A separating alloy must never pass.
Prediction (from E248's 0.70 read factor): 150 K reads about 105 K and fails; 120 K reads about 84 K
and falsely passes (p > 0.5).
If 120 K passes, rung 1's reading gets a clustering rule, pre-registered before use: when the cold
state clusters (α₁ > 0), the size factor is the one measured here (peak/T_c for separation), not the
ordering one.
EXPERIMENTS.md · lines 17441–17454
E248b RESULT (2026-09-27 23:09). Same protocol, runs/e248/:
exact T_c
peak
read T (÷0.95)
peak/T_c
p_rung1
verdict
500 K
332 K
349 K
0.664
0.000
not established: broad (FWHM/T 0.66)
150 K
96 K
101 K
0.640
0.000
not established: broad (0.71)
120 K
84 K
88 K
0.700
0.000
not established: broad (0.62)
The bar holds at both temperatures (p ≤ 0.1): no false pass.
The prediction is falsified. 120 K did not pass, but only because the broad-feature rule caught it:
the peak's upper half-width still reaches 90 K. The reading itself was below 90 K.
The read factor for separation is 0.67 ± 0.03 (three temperatures), not ordering's 0.95 ± 0.03.
The gap is real but narrow. A separation at about 95 K would peak near 64 K, its upper half-width would
end near 88 K, short of the window, and it would pass. That would be a false pass inside the window.
Related entries
E248 — E255 — the review's experiments: one per open question, parameters fixed (registered…