With the temperature grid extended to 30 K, does the ordering rung get every known answer right?
Yes. All nine hold: the 95 K separation now fails, a 60 K separation passes, and every ordering answer is unchanged. The 95 K margin is thin, and is stated.
In the log: extend rung 1's grid down to 30 K (pre-registered 2026-09-27 23:21)
confirmedDate 2026-09-27 23:21, as written in the logrung 1 · ordering0 predictions · 1 result paragraphEXPERIMENTS.md lines 17479–17494, lines 17496–17519
Pre-registration
The pre-registration, as written
E248d — extend rung 1's grid down to 30 K (pre-registered 2026-09-27 23:21)
Change. The geometric grid continues from 60 K down to 30 K at the same ratio (0.92). Then any
separation with T_c ≥ 90 K, whose peak reads at ≥ 0.64 × 90 ≈ 58 K, lies inside the sweep with room
below it. Cost: about 8 more temperatures per leg, most of them cheap and near-frozen.
Known answers, on the new grid (fresh sampling; the Isings are cheap):
clustering Ising 95 K, seeds 8 and 9: p_rung1 ≤ 0.1 (the E248c false pass must go);
clustering Ising 60 K, seeds 8 and 9: p_rung1 ≥ 0.9 (a separation below the window is allowed, and must
not be failed);
clustering Ising 300 K, seeds 8 and 9: corrected T within 10 %;
the ordering Isings K1, K4, K2a, K5 and K2b and the ring, seeds 6 and 7: E247's bars.
Mo–Ta on e6 is not re-sampled. Its transition is at 1120 K, and the added temperatures lie in its
frozen, ordered region, so its verdict cannot move. This is stated, not tested.
Prediction: every bar holds.
Results
EXPERIMENTS.md · line 17496
E248d RESULT (2026-09-28 00:51).runs/e248d/, all on the 30 K grid, read under E247 with the separation factor where
the cold state clusters. Every bar holds; the prediction holds.
The ordering answers read exactly as before above 60 K (same seeds and temperatures).
The 50 K Ising, read before as "still rising at the floor", is now a resolved peak at 50.5 K.
Stated margin: the 95 K separation reads 89.6 K after correction, just under 90 K. It fails because
its broad feature reaches the window, not on its temperature alone. Separation on this cell always
reads broad (FWHM/T 0.61–0.71 at every temperature tried), so the rule is systematic rather than lucky,
but the margin is thin. A factor fitted per temperature, or a larger cell, would widen it.
The review's first rung-1 question is closed. Rung 1 now fails decomposition inside the window, passes
it below the window, and reads its temperature within 5 % from 60 to 300 K.
The full record
This entry is written in 2 separate places in the log, shown here in log order.
EXPERIMENTS.md · lines 17479–17494
E248d — extend rung 1's grid down to 30 K (pre-registered 2026-09-27 23:21)
Change. The geometric grid continues from 60 K down to 30 K at the same ratio (0.92). Then any
separation with T_c ≥ 90 K, whose peak reads at ≥ 0.64 × 90 ≈ 58 K, lies inside the sweep with room
below it. Cost: about 8 more temperatures per leg, most of them cheap and near-frozen.
Known answers, on the new grid (fresh sampling; the Isings are cheap):
clustering Ising 95 K, seeds 8 and 9: p_rung1 ≤ 0.1 (the E248c false pass must go);
clustering Ising 60 K, seeds 8 and 9: p_rung1 ≥ 0.9 (a separation below the window is allowed, and must
not be failed);
clustering Ising 300 K, seeds 8 and 9: corrected T within 10 %;
the ordering Isings K1, K4, K2a, K5 and K2b and the ring, seeds 6 and 7: E247's bars.
Mo–Ta on e6 is not re-sampled. Its transition is at 1120 K, and the added temperatures lie in its
frozen, ordered region, so its verdict cannot move. This is stated, not tested.
Prediction: every bar holds.
EXPERIMENTS.md · lines 17496–17519
E248d RESULT (2026-09-28 00:51).runs/e248d/, all on the 30 K grid, read under E247 with the separation factor where
the cold state clusters. Every bar holds; the prediction holds.
The ordering answers read exactly as before above 60 K (same seeds and temperatures).
The 50 K Ising, read before as "still rising at the floor", is now a resolved peak at 50.5 K.
Stated margin: the 95 K separation reads 89.6 K after correction, just under 90 K. It fails because
its broad feature reaches the window, not on its temperature alone. Separation on this cell always
reads broad (FWHM/T 0.61–0.71 at every temperature tried), so the rule is systematic rather than lucky,
but the margin is thin. A factor fitted per temperature, or a larger cell, would widen it.
The review's first rung-1 question is closed. Rung 1 now fails decomposition inside the window, passes
it below the window, and reads its temperature within 5 % from 60 to 300 K.
Related entries
E248c — rung 1 corrects separation with its own factor (pre-registered 2026-09-27 23:09)
E247 — the requirement is one disordered phase: rung 1's pass rule changes (pre-registered…